Temporary Kitchen for HMP Channings Wood
HMP Channings Wood had a requirement to refurbish their existing catering facilities whilst still operating their normal day to day routines. They required a facility for a 4 month period and to cover 650 meals a day.
Working within a restricted footprint, we were able to design and install a 25 unit Portable Kitchen facility to meet all of HMP Channings Wood’s catering requirements. This stand alone facility was linked to mains gas supply and operated a full commercial kitchen including preparation area, three main production kitchens and temperature controlled storage.
We assign a Project Manager to every project to ensure that all processes run smoothly from initial design through to the installation and commissioning. At the beginning of this project, a time line and mandatory health and safety information was provided along with risk assessments, method statements and a safety plan for the works.
Throughout the duration of this project, we provided 24/7 technical support. Due to the sensitivity of the Home Office locations, our engineers make regular pre-arranged service visits to carry out Planned Preventative Maintenance (PPM) visits and any additional equipment training.
General Features of HMP Channings Wood
- Goods In Ramps – Solid timber construction and steel chequer plate non slip surface. Handrails and gradients supplied to building regulations.
- Building Skirts – To prevent access under and between units and fire risk from rubbish accumulation.
- Service Manifolds – Manifolds designed for LP or natural gas. Distribution installed for three phase electrical equipment.
- Electrical Distribution Boards – Commando sockets used for both board and Portable Kitchen unit connection, fast, flexible and safe.
- Foundation Pads – We construct foundation pads for both dry and/or wet laid blocks. Groundworks designed according to site requirements.
Health and Safety Features of HMP Channings Wood
- Ventilation Auto Gas Shut Off – Interlocked with the gas supply to automatically shut off the gas should the extraction not come on.
- Automatic Fire Suppression System – Automatic fire suppression as standard including fire detection devices, supplied upon request.
- Easy Clean Extraction Systems – 100% stainless steel balanced air input extraction with up to 60 air changes per hour.
- Fire Resistant Construction – All PKL units designed following health and safety guidelines to limit fire hazards.
Facility
25 unit Portable Kitchen facility to feed 650 meals a day
Reasons for Hire
Refurbishment of existing facility
Size
25 Portable Kitchen facility
Programme of Works
2 weeks
Length of Hire
4 months